Mitigation Monitoring and Reporting Matrix (continued)

 

 

Significant Impact Being Mitigated

 

Mitigation Measure

 

Responsibility for Implementation

 

Enforcement Responsibility

Monitoring Responsibility/ Frequency

 

Actions Indicating Compliance

Cultural Resources (cont.)

 

Roundhouse are available at the Library and Collections Department of the California State Railroad Museum in Sacramento. These original plans and early photographs shall be used when preparing the rehabilitation plan for this building to ensure that rehabilitation efforts will adequately preserve the historic architectural and structural integrity of the building.

 

 

 

 

Effects on the

4.D-1b: All Project Site development within 50 feet of

Site-specific developer(s) of

City of Brisbane approval

The Community

Approval of site-specific

historically

the Roundhouse or the Machinery & Equipment

properties within 50 feet of

authority for site-specific

Development Director shall

development within 50 feet

significant

building be designed to ensure their architectural

the Roundhouse and the

development within 50 feet

review proposed site-

of the Roundhouse and the

Roundhouse building

compatibility with the historic Roundhouse, and to

Machinery & Equipment

of the Roundhouse and the

specific development plans

Machinery & Equipment

DSP, DSP-V, CPP, &

CPP-V scenarios

ensure that new buildings do not overwhelm or unnecessarily contrast with these historic buildings. To this end, all development projects shall incorporate a

buildings

Machinery & Equipment buildings

for compliance with Mitigation Measure 4.D-1b prior to staff approval for

buildings in compliance with Mitigation Measure 4.D-1b.

minimum 50-foot structural setback and appropriate

development not subject to

heights, volumes, and materials for any proposed new

public hearings and before

buildings in the immediate vicinity to ensure

submittal to the Planning

compatibility with the Roundhouse and the Machinery

Commission for

& Equipment building. Appropriate heights of new

development projects

construction adjacent to the Roundhouse would be the

requiring public hearings.

same as (about 25 feet), or slightly greater than (i.e.,

up to 15 feet greater than), the existing height of the

building. Appropriate heights of new construction

adjacent to the Machinery & Equipment building would

be the same as (about 40 feet) or slightly greater than

(up to 10 feet greater than), the existing height of the

building. Appropriate materials for new construction in

the immediate vicinity of either building would be brick

cladding and/or cementitious materials painted a

similar dark red color, as well as Spanish tile roof

cladding. Appropriate volumes for new development

that would face the Roundhouse should mirror the

curve of the existing structure. Appropriate volumes for

new development in the vicinity of the Machinery &

Equipment building would be rectilinear in massing.

All development projects within 50 feet of the

Roundhouse or the Machinery & Equipment building

shall be subject to City design permit review and

approval prior to development.


Previous Page | Next Page